HL V-Series Air Cooled Chillers
HL V-15
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-15
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV15
Duty
cooling capacity @ 15°C(1)
kW
15
cooling capacity @ 7°C(2)
kW
12.5
(1)/(3) total absorbed power
kW
5.02
(1)compressor power
kW
4.1
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
9.54
maximum current
A
14.5
Compressor
model
Copeland
type
ZPD61KCE
Number of compressor
1
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
1
total nominal power
kW
0.37
(1) nominal air flow
m³/h
6500
Pump standard
3bar
CNP
CHL2F-40
total nominal power
kW
0.55
(1) water flow
m³/h
2.5/3.5
(1) available pressure
kPa
260/160
Tank
Tank Capacity
L
15
Water
connections
inlet/outlet(BSP)
inch
1"
Dimensions of
unit
depth
mm
1190
width
mm
730
height
mm
890
net weight
kg
195
Dimensions of
package
depth
mm
1330
width
mm
890
height
mm
1085
gross weight
kg
225
Sound
Sound Pressure Level (4)
dB(A)
60
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-20
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-20
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV20
Duty
cooling capacity @ 15°C(1)
kW
18.5
cooling capacity @ 7°C(2)
kW
15
(1)/(3) total absorbed power
kW
5.72
(1)compressor power
kW
4.8
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
10.86
maximum current
A
16.5
Compressor
model
Copeland
type
ZPD72KCE
Number of compressor
1
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
1
total nominal power
kW
0.37
(1) nominal air flow
m³/h
6500
Pump standard
3bar
CNP
CHL2F-40
total nominal power
kW
0.55
(1) water flow
m³/h
3/3.5
(1) available pressure
kPa
240/160
Tank
Tank Capacity
L
15
Water
connections
inlet/outlet(BSP)
inch
1"
Dimensions of
unit
depth
mm
1190
width
mm
730
height
mm
890
net weight
kg
175
Dimensions of
package
depth
mm
1400
width
mm
950
height
mm
1090
gross weight
kg
200
Sound
Sound Pressure Level (4)
dB(A)
60
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-30
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-30
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV30
Duty
cooling capacity @ 15°C(1)
kW
30
cooling capacity @ 7°C(2)
kW
25
(1)/(3) total absorbed power
kW
9.95
(1)compressor power
kW
8.1
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
18.8
maximum current
A
26.5
Compressor
model
Copeland
type
ZP(D)61KCE
Number of compressor
2
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
0.75
(1) nominal air flow
m³/h
13000
Pump standard
3bar
CNP
CHL8F-30
total nominal power
kW
1.1
(1) water flow
m³/h
4.5/11
(1) available pressure
kPa
300/180
Tank
Tank Capacity
L
30
Water
connections
inlet/outlet(BSP)
inch
1.1/4"
Dimensions of
unit
depth
mm
1420
width
mm
800
height
mm
960
net weight
kg
300
Dimensions of
package
depth
mm
1620
width
mm
1000
height
mm
1200
gross weight
kg
330
Sound
Sound Pressure Level (4)
dB(A)
62
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-40
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-40
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV40
Duty
cooling capacity @ 15°C(1)
kW
39
cooling capacity @ 7°C(2)
kW
30
(1)/(3) total absorbed power
kW
11.35
(1)compressor power
kW
9.5
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
21.55
maximum current
A
29.2
Compressor
model
Copeland
type
ZP(D)72KCE
Number of compressor
2
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
0.75
(1) nominal air flow
m³/h
13000
Pump standard
3bar
CNP
CHL8F-30
total nominal power
kW
1.1
(1) water flow
m³/h
5.5/11
(1) available pressure
kPa
280/180
Tank
Tank Capacity
L
30
Water
connections
inlet/outlet(BSP)
inch
1.1/4"
Dimensions of
unit
depth
mm
1520
width
mm
800
height
mm
960
net weight
kg
330
Dimensions of
package
depth
mm
1720
width
mm
1000
height
mm
1200
gross weight
kg
370
Sound
Sound Pressure Level (4)
dB(A)
62
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-50
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-50
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV50
Duty
cooling capacity @ 15°C(1)
kW
49
cooling capacity @ 7°C(2)
kW
38
(1)/(3) total absorbed power
kW
14.60
(1)compressor power
kW
11.6
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
27.7
maximum current
A
37.2
Compressor
model
Copeland
type
ZP(D)61KCE
Number of compressor
3
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
1.20
(1) nominal air flow
m³/h
19000
Pump standard
3bar
CNP
CHL12F-30
total nominal power
kW
1.8
(1) water flow
m³/h
7.5/16
(1) available pressure
kPa
350/200
Tank
Tank Capacity
L
60
Water
connections
inlet/outlet(BSP)
inch
1.1/2"
Dimensions of
unit
depth
mm
2000
width
mm
915
height
mm
1895
net weight
kg
450
Dimensions of
package
depth
mm
2300
width
mm
1050
height
mm
2150
gross weight
kg
490
Sound
Sound Pressure Level (4)
dB(A)
65
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-60
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-60
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV60
Duty
cooling capacity @ 15°C(1)
kW
58
cooling capacity @ 7°C(2)
kW
45
(1)/(3) total absorbed power
kW
17.50
(1)compressor power
kW
14.5
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
33.2
maximum current
A
43.6
Compressor
model
Copeland
type
ZP(D)72KCE
Number of compressor
3
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
1.20
(1) nominal air flow
m³/h
19000
Pump standard
3bar
CNP
CHL12F-30
total nominal power
kW
1.8
(1) water flow
m³/h
8.5/16
(1) available pressure
kPa
330/200
Tank
Tank Capacity
L
60
Water
connections
inlet/outlet(BSP)
inch
1.1/2"
Dimensions of
unit
depth
mm
2000
width
mm
915
height
mm
1895
net weight
kg
450
Dimensions of
package
depth
mm
2300
width
mm
1050
height
mm
2150
gross weight
kg
490
Sound
Sound Pressure Level (4)
dB(A)
65
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-70
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-70
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV70
Duty
cooling capacity @ 15°C(1)
kW
65
cooling capacity @ 7°C(2)
kW
50
(1)/(3) total absorbed power
kW
19.80
(1)compressor power
kW
16.1
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
37.6
maximum current
A
48.8
Compressor
model
Copeland
type
ZP(D)61KCE
Number of compressor
4
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
1.50
(1) nominal air flow
m³/h
25000
Pump standard
3bar
CNP
CHL16F-20
total nominal power
kW
2.2
(1) water flow
m³/h
9.5/20
(1) available pressure
kPa
240/170
Tank
Tank Capacity
L
100
Water
connections
inlet/outlet(BSP)
inch
2"
Dimensions of
unit
depth
mm
2000
width
mm
1095
height
mm
2050
net weight
kg
580
Dimensions of
package
depth
mm
2300
width
mm
1230
height
mm
2250
gross weight
kg
630
Sound
Sound Pressure Level (4)
dB(A)
67
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL V-90
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL V-90
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
Models
HLV90
Duty
cooling capacity @ 15°C(1)
kW
85
cooling capacity @ 7°C(2)
kW
60
(1)/(3) total absorbed power
kW
22.20
(1)compressor power
kW
18.5
Electric
Electric Supply
V/Ph/Hz
380-415/3/50
(1) nominal current
A
42.2
maximum current
A
56.7
Compressor
model
Copeland
type
ZP(D)72KCE
Number of compressor
4
Number of circuits
1
Refrigerant Type
R410A
Axial Fans
number of fan
2
total nominal power
kW
1.50
(1) nominal air flow
m³/h
25000
Pump standard
3bar
CNP
CHL16F-20
total nominal power
kW
2.2
(1) water flow
m³/h
11.5/20
(1) available pressure
kPa
220/170
Tank
Tank Capacity
L
100
Water
connections
inlet/outlet(BSP)
inch
2"
Dimensions of
unit
depth
mm
2000
width
mm
1095
height
mm
2050
net weight
kg
600
Dimensions of
package
depth
mm
2300
width
mm
1230
height
mm
2250
gross weight
kg
650
Sound
Sound Pressure Level (4)
dB(A)
67
Note
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.

HL V-15
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV15 |
Duty |
cooling capacity @ 15°C(1) |
kW |
15 |
cooling capacity @ 7°C(2) |
kW |
12.5 |
|
(1)/(3) total absorbed power |
kW |
5.02 |
|
|
(1)compressor power |
kW |
4.1 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
9.54 |
|
|
maximum current |
A |
14.5 |
Compressor |
model |
Copeland |
|
type |
ZPD61KCE |
||
Number of compressor |
1 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
1 |
|
total nominal power |
kW |
0.37 |
|
|
(1) nominal air flow |
m³/h |
6500 |
Pump standard
3bar |
CNP |
CHL2F-40 |
|
total nominal power
|
kW |
0.55 |
|
(1) water flow |
m³/h |
2.5/3.5 |
|
|
(1) available pressure |
kPa |
260/160 |
Tank |
Tank Capacity |
L |
15 |
Water
connections |
inlet/outlet(BSP) |
inch |
1" |
Dimensions of
unit |
depth |
mm |
1190 |
width |
mm |
730 |
|
height |
mm |
890 |
|
|
net weight |
kg |
195 |
Dimensions of
package |
depth |
mm |
1330 |
width |
mm |
890 |
|
height |
mm |
1085 |
|
|
gross weight |
kg |
225 |
Sound |
Sound Pressure Level (4) |
dB(A) |
60 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-20
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV20 |
Duty |
cooling capacity @ 15°C(1) |
kW |
18.5 |
cooling capacity @ 7°C(2) |
kW |
15 |
|
(1)/(3) total absorbed power |
kW |
5.72 |
|
|
(1)compressor power |
kW |
4.8 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
10.86 |
|
|
maximum current |
A |
16.5 |
Compressor |
model |
Copeland |
|
type |
ZPD72KCE |
||
Number of compressor |
1 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
1 |
|
total nominal power |
kW |
0.37 |
|
|
(1) nominal air flow |
m³/h |
6500 |
Pump standard
3bar |
CNP |
CHL2F-40 |
|
total nominal power
|
kW |
0.55 |
|
(1) water flow |
m³/h |
3/3.5 |
|
|
(1) available pressure |
kPa |
240/160 |
Tank |
Tank Capacity |
L |
15 |
Water
connections |
inlet/outlet(BSP) |
inch |
1" |
Dimensions of
unit |
depth |
mm |
1190 |
width |
mm |
730 |
|
height |
mm |
890 |
|
|
net weight |
kg |
175 |
Dimensions of
package |
depth |
mm |
1400 |
width |
mm |
950 |
|
height |
mm |
1090 |
|
|
gross weight |
kg |
200 |
Sound |
Sound Pressure Level (4) |
dB(A) |
60 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-30
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV30 |
Duty |
cooling capacity @ 15°C(1) |
kW |
30 |
cooling capacity @ 7°C(2) |
kW |
25 |
|
(1)/(3) total absorbed power |
kW |
9.95 |
|
|
(1)compressor power |
kW |
8.1 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
18.8 |
|
|
maximum current |
A |
26.5 |
Compressor |
model |
Copeland |
|
type |
ZP(D)61KCE |
||
Number of compressor |
2 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
0.75 |
|
|
(1) nominal air flow |
m³/h |
13000 |
Pump standard
3bar |
CNP |
CHL8F-30 |
|
total nominal power
|
kW |
1.1 |
|
(1) water flow |
m³/h |
4.5/11 |
|
|
(1) available pressure |
kPa |
300/180 |
Tank |
Tank Capacity |
L |
30 |
Water
connections |
inlet/outlet(BSP) |
inch |
1.1/4" |
Dimensions of
unit |
depth |
mm |
1420 |
width |
mm |
800 |
|
height |
mm |
960 |
|
|
net weight |
kg |
300 |
Dimensions of
package |
depth |
mm |
1620 |
width |
mm |
1000 |
|
height |
mm |
1200 |
|
|
gross weight |
kg |
330 |
Sound |
Sound Pressure Level (4) |
dB(A) |
62 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-40
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV40 |
Duty |
cooling capacity @ 15°C(1) |
kW |
39 |
cooling capacity @ 7°C(2) |
kW |
30 |
|
(1)/(3) total absorbed power |
kW |
11.35 |
|
|
(1)compressor power |
kW |
9.5 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
21.55 |
|
|
maximum current |
A |
29.2 |
Compressor |
model |
Copeland |
|
type |
ZP(D)72KCE |
||
Number of compressor |
2 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
0.75 |
|
|
(1) nominal air flow |
m³/h |
13000 |
Pump standard
3bar |
CNP |
CHL8F-30 |
|
total nominal power
|
kW |
1.1 |
|
(1) water flow |
m³/h |
5.5/11 |
|
|
(1) available pressure |
kPa |
280/180 |
Tank |
Tank Capacity |
L |
30 |
Water
connections |
inlet/outlet(BSP) |
inch |
1.1/4" |
Dimensions of
unit |
depth |
mm |
1520 |
width |
mm |
800 |
|
height |
mm |
960 |
|
|
net weight |
kg |
330 |
Dimensions of
package |
depth |
mm |
1720 |
width |
mm |
1000 |
|
height |
mm |
1200 |
|
|
gross weight |
kg |
370 |
Sound |
Sound Pressure Level (4) |
dB(A) |
62 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-50
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
Models |
|
HLV50 |
Duty |
cooling capacity @ 15°C(1) |
kW |
49 |
cooling capacity @ 7°C(2) |
kW |
38 |
|
(1)/(3) total absorbed power |
kW |
14.60 |
|
|
(1)compressor power |
kW |
11.6 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
27.7 |
|
|
maximum current |
A |
37.2 |
Compressor |
model |
Copeland |
|
type |
ZP(D)61KCE |
||
Number of compressor |
3 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
1.20 |
|
|
(1) nominal air flow |
m³/h |
19000 |
Pump standard
3bar |
CNP |
CHL12F-30 |
|
total nominal power
|
kW |
1.8 |
|
(1) water flow |
m³/h |
7.5/16 |
|
|
(1) available pressure |
kPa |
350/200 |
Tank |
Tank Capacity |
L |
60 |
Water
connections |
inlet/outlet(BSP) |
inch |
1.1/2" |
Dimensions of
unit |
depth |
mm |
2000 |
width |
mm |
915 |
|
height |
mm |
1895 |
|
|
net weight |
kg |
450 |
Dimensions of
package |
depth |
mm |
2300 |
width |
mm |
1050 |
|
height |
mm |
2150 |
|
|
gross weight |
kg |
490 |
Sound |
Sound Pressure Level (4) |
dB(A) |
65 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-60
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV60 |
Duty |
cooling capacity @ 15°C(1) |
kW |
58 |
cooling capacity @ 7°C(2) |
kW |
45 |
|
(1)/(3) total absorbed power |
kW |
17.50 |
|
|
(1)compressor power |
kW |
14.5 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
33.2 |
|
|
maximum current |
A |
43.6 |
Compressor |
model |
Copeland |
|
type |
ZP(D)72KCE |
||
Number of compressor |
3 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
1.20 |
|
|
(1) nominal air flow |
m³/h |
19000 |
Pump standard
3bar |
CNP |
CHL12F-30 |
|
total nominal power
|
kW |
1.8 |
|
(1) water flow |
m³/h |
8.5/16 |
|
|
(1) available pressure |
kPa |
330/200 |
Tank |
Tank Capacity |
L |
60 |
Water
connections |
inlet/outlet(BSP) |
inch |
1.1/2" |
Dimensions of
unit |
depth |
mm |
2000 |
width |
mm |
915 |
|
height |
mm |
1895 |
|
|
net weight |
kg |
450 |
Dimensions of
package |
depth |
mm |
2300 |
width |
mm |
1050 |
|
height |
mm |
2150 |
|
|
gross weight |
kg |
490 |
Sound |
Sound Pressure Level (4) |
dB(A) |
65 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-70
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV70 |
Duty |
cooling capacity @ 15°C(1) |
kW |
65 |
cooling capacity @ 7°C(2) |
kW |
50 |
|
(1)/(3) total absorbed power |
kW |
19.80 |
|
|
(1)compressor power |
kW |
16.1 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
37.6 |
|
|
maximum current |
A |
48.8 |
Compressor |
model |
Copeland |
|
type |
ZP(D)61KCE |
||
Number of compressor |
4 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
1.50 |
|
|
(1) nominal air flow |
m³/h |
25000 |
Pump standard
3bar |
CNP |
CHL16F-20 |
|
total nominal power
|
kW |
2.2 |
|
(1) water flow |
m³/h |
9.5/20 |
|
|
(1) available pressure |
kPa |
240/170 |
Tank |
Tank Capacity |
L |
100 |
Water
connections |
inlet/outlet(BSP) |
inch |
2" |
Dimensions of
unit |
depth |
mm |
2000 |
width |
mm |
1095 |
|
height |
mm |
2050 |
|
|
net weight |
kg |
580 |
Dimensions of
package |
depth |
mm |
2300 |
width |
mm |
1230 |
|
height |
mm |
2250 |
|
|
gross weight |
kg |
630 |
Sound |
Sound Pressure Level (4) |
dB(A) |
67 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL V-90
- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C

- Stainless Steel Plate Heat Exchanger
- Microprocessor Control
- Digital Scroll Variable Speed
- Precise Infinite Capacity Modulation 10%-100%
- Temperature Control within ±0.5°C
- Lower Operating Cost
- More Efficient Than Using Hot Gas Pass
- Quieter Operation and Higher Reliability
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -15°C to 43°C
- Water Temperature: From -5°C to 35°C
|
|
|
HLV90 |
Duty |
cooling capacity @ 15°C(1) |
kW |
85 |
cooling capacity @ 7°C(2) |
kW |
60 |
|
(1)/(3) total absorbed power |
kW |
22.20 |
|
|
(1)compressor power |
kW |
18.5 |
Electric |
Electric Supply |
V/Ph/Hz |
380-415/3/50 |
(1) nominal current |
A |
42.2 |
|
|
maximum current |
A |
56.7 |
Compressor |
model |
Copeland |
|
type |
ZP(D)72KCE |
||
Number of compressor |
4 |
||
Number of circuits |
1 |
||
|
Refrigerant Type |
|
R410A |
Axial Fans |
number of fan |
2 |
|
total nominal power |
kW |
1.50 |
|
|
(1) nominal air flow |
m³/h |
25000 |
Pump standard
3bar |
CNP |
CHL16F-20 |
|
total nominal power
|
kW |
2.2 |
|
(1) water flow |
m³/h |
11.5/20 |
|
|
(1) available pressure |
kPa |
220/170 |
Tank |
Tank Capacity |
L |
100 |
Water
connections |
inlet/outlet(BSP) |
inch |
2" |
Dimensions of
unit |
depth |
mm |
2000 |
width |
mm |
1095 |
|
height |
mm |
2050 |
|
|
net weight |
kg |
600 |
Dimensions of
package |
depth |
mm |
2300 |
width |
mm |
1230 |
|
height |
mm |
2250 |
|
|
gross weight |
kg |
650 |
Sound |
Sound Pressure Level (4) |
dB(A) |
67 |
Note |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |