HL i-Series Air Cooled Chillers
HL i-3
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-3
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-3
Duty
cooling capacity @ 15°C(1)
kW
3
cooling capacity @ 7°C(2)
kW
2.5
compressor power(3)
kW
0.7
Electric
supply
V/Ph/Hz
230/1/50
nominal current(1)
A
5.9
maximum current
A
7.7
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.05
nominal air flow(1)
m³/h
1100
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
0.45/5.1
available pressure(1)
kPa
350/80
Tank capacity
tank
L
25
Water
connections
inlet/outlet (BSP)
inch
1/2"
Dimensions of
unit
width
mm
689
depth
mm
548
height
mm
876
net weight
kg
105
Dimensions of
package
width
mm
775
depth
mm
650
height
mm
1060
gross weight
kg
111
Sound
pressure level
dB(4)
A
45
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-5
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-5
- -Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-5
Duty
cooling capacity @ 15°C(1)
kW
4.5
cooling capacity @ 7°C(2)
kW
3.4
compressor power(3)
kW
1.25
Electric
supply
V/Ph/Hz
230/1/50
nominal current(1)
A
8.7
maximum current
A
10.6
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.14
nominal air flow(1)
m³/h
3100
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
0.58/5.1
available pressure(1)
kPa
315/80
Tank capacity
tank
L
25
Water
connections
inlet/outlet (BSP)
inch
1/2"
Dimensions of
unit
width
mm
689
depth
mm
548
height
mm
876
net weight
kg
118
Dimensions of
package
width
mm
775
depth
mm
650
height
mm
1060
gross weight
kg
124
Sound
pressure level
dB(4)
A
49
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-8
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-8
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-8
Duty
cooling capacity @ 15°C(1)
kW
7.2
cooling capacity @ 7°C(2)
kW
5.5
compressor power(3)
kW
1.7
Electric
supply
V/Ph/Hz
230/1/50
nominal current(1)
A
11.2
maximum current
A
13.7
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.17
nominal air flow(1)
m³/h
4000
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
0.9/5.1
available pressure(1)
kPa
300/80
Tank capacity
tank
L
30
Water
connections
inlet/outlet (BSP)
inch
3/4"
Dimensions of
unit
width
mm
689
depth
mm
548
height
mm
876
net weight
kg
135
Dimensions of
package
width
mm
775
depth
mm
650
height
mm
1060
gross weight
kg
145
Sound
pressure level
dB(4)
A
49
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-9
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-9
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-9
Duty
cooling capacity @ 15°C(1)
kW
7.5
cooling capacity @ 7°C(2)
kW
5.3
compressor power(3)
kW
1.72
Electric
supply
V/Ph/Hz
380-415/3/50
nominal current(1)
A
3.63
maximum current
A
4.8
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.15
nominal air flow(1)
m³/h
3800
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
0.89/5.1
available pressure(1)
kPa
410/115
Tank capacity
tank
L
60
Water
connections
inlet/outlet (BSP)
inch
3/4"
Dimensions of
unit
width
mm
538
depth
mm
1096
height
mm
1219
net weight
kg
165
Dimensions of
package
width
mm
630
depth
mm
1155
height
mm
1450
gross weight
kg
200
Sound
pressure level
dB(4)
A
52
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-10
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-10
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-10
Duty
cooling capacity @ 15°C(1)
kW
9.7
cooling capacity @ 7°C(2)
kW
6.8
compressor power(3)
kW
2.1
Electric
supply
V/Ph/Hz
380-415/3/50
nominal current(1)
A
4.22
maximum current
A
5.7
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.15
nominal air flow(1)
m³/h
3800
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
1.1/5.1
available pressure(1)
kPa
505/115
Tank capacity
tank
L
60
Water
connections
inlet/outlet (BSP)
inch
3/4"
Dimensions of
unit
width
mm
538
depth
mm
1096
height
mm
1219
net weight
kg
170
Dimensions of
package
width
mm
630
depth
mm
1155
height
mm
1450
gross weight
kg
205
Sound
pressure level
dB(4)
A
52
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-15
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-15
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-15
Duty
cooling capacity @ 15°C(1)
kW
13
cooling capacity @ 7°C(2)
kW
9.9
compressor power(3)
kW
3.65
Electric
supply
V/Ph/Hz
380-415/3/51
nominal current(1)
A
7.65
maximum current
A
9.5
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.61
nominal air flow(1)
m³/h
6500
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
1.6/8
available pressure(1)
kPa
315/75
Tank capacity
tank
L
110
Water
connections
inlet/outlet (BSP)
inch
1"
Dimensions of
unit
width
mm
743
depth
mm
1203
height
mm
1412
net weight
kg
205
Dimensions of
package
width
mm
880
depth
mm
1285
height
mm
1615
gross weight
kg
240
Sound
pressure level
dB(4)
A
55
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-20
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-20
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-20
Duty
cooling capacity @ 15°C(1)
kW
20
cooling capacity @ 7°C(2)
kW
14.5
compressor power(3)
kW
5.45
Electric
supply
V/Ph/Hz
380-415/3/52
nominal current(1)
A
10.4
maximum current
A
14.3
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.61
nominal air flow(1)
m³/h
6500
Pump 3bar
No. of pump
1
total nominal power
kW
0.55
water flow(1)
m³/h
2.5/8
available pressure(1)
kPa
300/75
Tank capacity
tank
L
110
Water
connections
inlet/outlet (BSP)
inch
1"
Dimensions of
unit
width
mm
743
depth
mm
1203
height
mm
1412
net weight
kg
235
Dimensions of
package
width
mm
880
depth
mm
1285
height
mm
1615
gross weight
kg
270
Sound
pressure level
dB(4)
A
55
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-30
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-30
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-30
Duty
cooling capacity @ 15°C(1)
kW
28.8
cooling capacity @ 7°C(2)
kW
20.5
compressor power(3)
kW
7.3
Electric
supply
V/Ph/Hz
380-415/3/53
nominal current(1)
A
14.1
maximum current
A
20.8
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
1
total nominal power
kW
0.78
nominal air flow(1)
m³/h
8600
Pump 3bar
No. of pump
1
total nominal power
kW
1.1
water flow(1)
m³/h
3.7/12
available pressure(1)
kPa
345/185
Tank capacity
tank
L
175
Water
connections
inlet/outlet
inch (BSP)
1.1/2"
Dimensions of
unit
width
mm
743
depth
mm
1766
height
mm
1415
net weight
kg
340
Dimensions of
package
width
mm
880
depth
mm
1835
height
mm
1615
gross weight
kg
380
Sound
pressure level
dB(4)
A
56
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-40
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-40
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-40
Duty
cooling capacity @ 15°C(1)
kW
38
cooling capacity @ 7°C(2)
kW
28
compressor power(3)
kW
9.2
Electric
supply
V/Ph/Hz
380-415/3/54
nominal current(1)
A
17
maximum current
A
27.2
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.22
nominal air flow(1)
m³/h
13000
Pump 3bar
No. of pump
1
total nominal power
kW
1.1
water flow(1)
m³/h
4.9/12
available pressure(1)
kPa
320/185
Tank capacity
tank
L
250
Water
connections
inlet/outlet (BSP)
inch
1.1/2"
Dimensions of
unit
width
mm
743
depth
mm
1766
height
mm
1409
net weight
kg
432
Dimensions of
package
width
mm
880
depth
mm
1835
height
mm
1615
gross weight
kg
457
Sound
pressure level
dB(4)
A
56
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-50
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-50
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-50
Duty
cooling capacity @ 15°C(1)
kW
46
cooling capacity @ 7°C(2)
kW
33.5
compressor power(3)
kW
12.3
Electric
supply
V/Ph/Hz
380-415/3/55
nominal current(1)
A
22
maximum current
A
33.4
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.22
nominal air flow(1)
m³/h
12400
Pump 3bar
No. of pump
1
total nominal power
kW
1.1
water flow(1)
m³/h
6.0/12
available pressure(1)
kPa
310/185
Tank capacity
tank
L
250
Water
connections
inlet/outlet (BSP)
inch
1.1/2"
Dimensions of
unit
width
mm
743
depth
mm
1766
height
mm
1409
net weight
kg
435
Dimensions of
package
width
mm
880
depth
mm
1835
height
mm
1615
gross weight
kg
460
Sound
pressure level
dB(4)
A
56
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-55
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-55
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-55
Duty
cooling capacity @ 15°C(1)
kW
53
cooling capacity @ 7°C(2)
kW
37.5
compressor power(3)
kW
12.5
Electric
supply
V/Ph/Hz
380-415/3/56
nominal current(1)
A
23
maximum current
A
33.5
Compressor
No. of compressor
1
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.56
nominal air flow(1)
m³/h
17200
Pump 3bar
No. of pump
1
total nominal power
kW
1.1
water flow(1)
m³/h
6.9/12
available pressure(1)
kPa
290/185
Tank capacity
tank
L
300
Water
connections
inlet/outlet (BSP)
inch
1.1/2"
Dimensions of
unit
width
mm
743
depth
mm
1966
height
mm
1519
net weight
kg
460
Dimensions of
package
width
mm
880
depth
mm
2035
height
mm
1725
gross weight
kg
490
Sound
pressure level
dB(4)
A
57
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-70
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-70
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-70
Duty
cooling capacity @ 15°C(1)
kW
63
cooling capacity @ 7°C(2)
kW
45
compressor power(3)
kW
2×7.3
Electric
supply
V/Ph/Hz
380-415/3/57
nominal current(1)
A
27.5
maximum current
A
38.6
Compressor
No. of compressor
2
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.56
nominal air flow(1)
m³/h
17200
Pump 3bar
No. of pump
1
total nominal power
kW
1.5
water flow(1)
m³/h
7.6/12
available pressure(1)
kPa
385/235
Tank capacity
tank
L
400
Water
connections
inlet/outlet (BSP)
inch
2"
Dimensions of
unit
width
mm
892
depth
mm
2330
height
mm
2055
net weight
kg
800
Dimensions of
package
width
mm
990
depth
mm
2435
height
mm
2250
gross weight
kg
845
Sound
pressure level
dB(4)
A
58
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-90
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-90
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-90
Duty
cooling capacity @ 15°C(1)
kW
90.5
cooling capacity @ 7°C(2)
kW
66
compressor power(3)
kW
2×12.3
Electric
supply
V/Ph/Hz
380-415/3/58
nominal current(1)
A
47.7
maximum current
A
69.8
Compressor
No. of compressor
2
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.96
nominal air flow(1)
m³/h
26856
Pump 3bar
No. of pump
1
total nominal power
kW
1.85
water flow(1)
m³/h
12.1/25
available pressure(1)
kPa
290/110
Tank capacity
tank
L
400
Water
connections
inlet/outlet (BSP)
inch
2"
Dimensions of
unit
width
mm
892
depth
mm
2330
height
mm
2055
net weight
kg
880
Dimensions of
package
width
mm
990
depth
mm
2435
height
mm
2250
gross weight
kg
950
Sound
pressure level
dB(4)
A
59
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-105
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-105
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-105
Duty
cooling capacity @ 15°C(1)
kW
103
cooling capacity @ 7°C(2)
kW
76
compressor power(3)
kW
2×12.5
Electric
supply
V/Ph/Hz
380-415/3/59
nominal current(1)
A
48
maximum current
A
70
Compressor
No. of compressor
2
Number of circuits
1
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
1.96
nominal air flow(1)
m³/h
26800
Pump 3bar
No. of pump
1
total nominal power
kW
1.85
water flow(1)
m³/h
13.9/25
available pressure(1)
kPa
280/110
Tank capacity
tank
L
400
Water
connections
inlet/outlet (BSP)
inch
2"
Dimensions of
unit
width
mm
892
depth
mm
2330
height
mm
2055
net weight
kg
880
Dimensions of
package
width
mm
990
depth
mm
2435
height
mm
2250
gross weight
kg
950
Sound
pressure level
dB(4)
A
59
Note:
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-150
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-150
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-150
Duty
cooling capacity @ 15°C(1)
kW
152
cooling capacity @ 7°C(2)
kW
109
compressor power(3)
kW
4×9.2
Electric
supply
V/Ph/Hz
380-415/3/60
nominal current(1)
A
76.4
maximum current
A
108.7
Compressor
No. of compressor
4
Number of circuits
2
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
4.00
nominal air flow(1)
m³/h
44000
Pump 3bar
No. of pump
1
total nominal power
kW
5.5
water flow(1)
m³/h
19.3/60
available pressure(1)
kPa
335/205
Tank capacity
tank
L
600
Water
connections
inlet/outlet (BSP)
inch
2.1/2"
Dimensions of
unit
width
mm
1250
depth
mm
3694
height
mm
1976
net weight
kg
1695
Dimensions of
package
width
mm
1395
depth
mm
3815
height
mm
2230
gross weight
kg
1745
Sound
pressure level
dB(4)
A
63
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.
HL i-180
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Read more...
HL i-180
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model
HL i-180
Duty
cooling capacity @ 15°C(1)
kW
182
cooling capacity @ 7°C(2)
kW
131
compressor power(3)
kW
4×12.3
Electric
supply
V/Ph/Hz
380-415/3/61
nominal current(1)
A
93.6
maximum current
A
135
Compressor
No. of compressor
4
Number of circuits
2
Refrigerant
R407c
Axial Fans
No. of fan
2
total nominal power
kW
4.00
nominal air flow(1)
m³/h
44000
Pump 3bar
No. of pump
1
total nominal power
kW
5.5
water flow(1)
m³/h
23.2/60
available pressure(1)
kPa
330/205
Tank capacity
tank
L
600
Water
connections
inlet/outlet (BSP)
inch
2.1/2"
Dimensions of
unit
width
mm
1250
depth
mm
3694
height
mm
1976
net weight
kg
1700
Dimensions of
package
width
mm
1395
depth
mm
3815
height
mm
2230
gross weight
kg
1750
Sound
pressure level
dB(4)
A
63
Note:
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C.
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C.
(3) refers to compressor, fans,
and pump absorbed power.
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground.

HL i-3
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-3 |
Duty |
cooling capacity @ 15°C(1) |
kW |
3 |
cooling capacity @ 7°C(2) |
kW |
2.5 |
|
|
compressor power(3) |
kW |
0.7 |
Electric
supply |
V/Ph/Hz |
230/1/50 |
|
nominal current(1) |
A |
5.9 |
|
|
maximum current |
A |
7.7 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.05 |
|
|
nominal air flow(1) |
m³/h |
1100 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
0.45/5.1 |
|
|
available pressure(1) |
kPa |
350/80 |
Tank capacity |
tank |
L |
25 |
Water
connections |
inlet/outlet (BSP) |
inch |
1/2" |
Dimensions of
unit |
width |
mm |
689 |
depth |
mm |
548 |
|
height |
mm |
876 |
|
|
net weight |
kg |
105 |
Dimensions of
package |
width |
mm |
775 |
depth |
mm |
650 |
|
height |
mm |
1060 |
|
|
gross weight |
kg |
111 |
Sound
pressure level |
dB(4) |
A |
45 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-5
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- -Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-5 |
Duty |
cooling capacity @ 15°C(1) |
kW |
4.5 |
cooling capacity @ 7°C(2) |
kW |
3.4 |
|
|
compressor power(3) |
kW |
1.25 |
Electric
supply |
V/Ph/Hz |
230/1/50 |
|
nominal current(1) |
A |
8.7 |
|
|
maximum current |
A |
10.6 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.14 |
|
|
nominal air flow(1) |
m³/h |
3100 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
0.58/5.1 |
|
|
available pressure(1) |
kPa |
315/80 |
Tank capacity |
tank |
L |
25 |
Water
connections |
inlet/outlet (BSP) |
inch |
1/2" |
Dimensions of
unit |
width |
mm |
689 |
depth |
mm |
548 |
|
height |
mm |
876 |
|
|
net weight |
kg |
118 |
Dimensions of
package |
width |
mm |
775 |
depth |
mm |
650 |
|
height |
mm |
1060 |
|
|
gross weight |
kg |
124 |
Sound
pressure level |
dB(4) |
A |
49 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-8
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-8 |
Duty |
cooling capacity @ 15°C(1) |
kW |
7.2 |
cooling capacity @ 7°C(2) |
kW |
5.5 |
|
|
compressor power(3) |
kW |
1.7 |
Electric
supply |
V/Ph/Hz |
230/1/50 |
|
nominal current(1) |
A |
11.2 |
|
|
maximum current |
A |
13.7 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.17 |
|
|
nominal air flow(1) |
m³/h |
4000 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
0.9/5.1 |
|
|
available pressure(1) |
kPa |
300/80 |
Tank capacity |
tank |
L |
30 |
Water
connections |
inlet/outlet (BSP) |
inch |
3/4" |
Dimensions of
unit |
width |
mm |
689 |
depth |
mm |
548 |
|
height |
mm |
876 |
|
|
net weight |
kg |
135 |
Dimensions of
package |
width |
mm |
775 |
depth |
mm |
650 |
|
height |
mm |
1060 |
|
|
gross weight |
kg |
145 |
Sound
pressure level |
dB(4) |
A |
49 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-9
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-9 |
Duty |
cooling capacity @ 15°C(1) |
kW |
7.5 |
cooling capacity @ 7°C(2) |
kW |
5.3 |
|
|
compressor power(3) |
kW |
1.72 |
Electric
supply |
V/Ph/Hz |
380-415/3/50 |
|
nominal current(1) |
A |
3.63 |
|
|
maximum current |
A |
4.8 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.15 |
|
|
nominal air flow(1) |
m³/h |
3800 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
0.89/5.1 |
|
|
available pressure(1) |
kPa |
410/115 |
Tank capacity |
tank |
L |
60 |
Water
connections |
inlet/outlet (BSP) |
inch |
3/4" |
Dimensions of
unit |
width |
mm |
538 |
depth |
mm |
1096 |
|
height |
mm |
1219 |
|
|
net weight |
kg |
165 |
Dimensions of
package |
width |
mm |
630 |
depth |
mm |
1155 |
|
height |
mm |
1450 |
|
|
gross weight |
kg |
200 |
Sound
pressure level |
dB(4) |
A |
52 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-10
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-10 |
Duty |
cooling capacity @ 15°C(1) |
kW |
9.7 |
cooling capacity @ 7°C(2) |
kW |
6.8 |
|
|
compressor power(3) |
kW |
2.1 |
Electric
supply |
V/Ph/Hz |
380-415/3/50 |
|
nominal current(1) |
A |
4.22 |
|
|
maximum current |
A |
5.7 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.15 |
|
|
nominal air flow(1) |
m³/h |
3800 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
1.1/5.1 |
|
|
available pressure(1) |
kPa |
505/115 |
Tank capacity |
tank |
L |
60 |
Water
connections |
inlet/outlet (BSP) |
inch |
3/4" |
Dimensions of
unit |
width |
mm |
538 |
depth |
mm |
1096 |
|
height |
mm |
1219 |
|
|
net weight |
kg |
170 |
Dimensions of
package |
width |
mm |
630 |
depth |
mm |
1155 |
|
height |
mm |
1450 |
|
|
gross weight |
kg |
205 |
Sound
pressure level |
dB(4) |
A |
52 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-15
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-15 |
Duty |
cooling capacity @ 15°C(1) |
kW |
13 |
cooling capacity @ 7°C(2) |
kW |
9.9 |
|
|
compressor power(3) |
kW |
3.65 |
Electric
supply |
V/Ph/Hz |
380-415/3/51 |
|
nominal current(1) |
A |
7.65 |
|
|
maximum current |
A |
9.5 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.61 |
|
|
nominal air flow(1) |
m³/h |
6500 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
1.6/8 |
|
|
available pressure(1) |
kPa |
315/75 |
Tank capacity |
tank |
L |
110 |
Water
connections |
inlet/outlet (BSP) |
inch |
1" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1203 |
|
height |
mm |
1412 |
|
|
net weight |
kg |
205 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
1285 |
|
height |
mm |
1615 |
|
|
gross weight |
kg |
240 |
Sound
pressure level |
dB(4) |
A |
55 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-20
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-20 |
Duty |
cooling capacity @ 15°C(1) |
kW |
20 |
cooling capacity @ 7°C(2) |
kW |
14.5 |
|
|
compressor power(3) |
kW |
5.45 |
Electric
supply |
V/Ph/Hz |
380-415/3/52 |
|
nominal current(1) |
A |
10.4 |
|
|
maximum current |
A |
14.3 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.61 |
|
|
nominal air flow(1) |
m³/h |
6500 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
0.55 |
|
water flow(1) |
m³/h |
2.5/8 |
|
|
available pressure(1) |
kPa |
300/75 |
Tank capacity |
tank |
L |
110 |
Water
connections |
inlet/outlet (BSP) |
inch |
1" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1203 |
|
height |
mm |
1412 |
|
|
net weight |
kg |
235 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
1285 |
|
height |
mm |
1615 |
|
|
gross weight |
kg |
270 |
Sound
pressure level |
dB(4) |
A |
55 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-30
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-30 |
Duty |
cooling capacity @ 15°C(1) |
kW |
28.8 |
cooling capacity @ 7°C(2) |
kW |
20.5 |
|
|
compressor power(3) |
kW |
7.3 |
Electric
supply |
V/Ph/Hz |
380-415/3/53 |
|
nominal current(1) |
A |
14.1 |
|
|
maximum current |
A |
20.8 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
1 |
|
total nominal power |
kW |
0.78 |
|
|
nominal air flow(1) |
m³/h |
8600 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.1 |
|
water flow(1) |
m³/h |
3.7/12 |
|
|
available pressure(1) |
kPa |
345/185 |
Tank capacity |
tank |
L |
175 |
Water
connections |
inlet/outlet |
inch (BSP) |
1.1/2" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1766 |
|
height |
mm |
1415 |
|
|
net weight |
kg |
340 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
1835 |
|
height |
mm |
1615 |
|
|
gross weight |
kg |
380 |
Sound
pressure level |
dB(4) |
A |
56 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-40
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-40 |
Duty |
cooling capacity @ 15°C(1) |
kW |
38 |
cooling capacity @ 7°C(2) |
kW |
28 |
|
|
compressor power(3) |
kW |
9.2 |
Electric
supply |
V/Ph/Hz |
380-415/3/54 |
|
nominal current(1) |
A |
17 |
|
|
maximum current |
A |
27.2 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.22 |
|
|
nominal air flow(1) |
m³/h |
13000 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.1 |
|
water flow(1) |
m³/h |
4.9/12 |
|
|
available pressure(1) |
kPa |
320/185 |
Tank capacity |
tank |
L |
250 |
Water
connections |
inlet/outlet (BSP) |
inch |
1.1/2" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1766 |
|
height |
mm |
1409 |
|
|
net weight |
kg |
432 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
1835 |
|
height |
mm |
1615 |
|
|
gross weight |
kg |
457 |
Sound
pressure level |
dB(4) |
A |
56 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-50
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-50 |
Duty |
cooling capacity @ 15°C(1) |
kW |
46 |
cooling capacity @ 7°C(2) |
kW |
33.5 |
|
|
compressor power(3) |
kW |
12.3 |
Electric
supply |
V/Ph/Hz |
380-415/3/55 |
|
nominal current(1) |
A |
22 |
|
|
maximum current |
A |
33.4 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.22 |
|
|
nominal air flow(1) |
m³/h |
12400 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.1 |
|
water flow(1) |
m³/h |
6.0/12 |
|
|
available pressure(1) |
kPa |
310/185 |
Tank capacity |
tank |
L |
250 |
Water
connections |
inlet/outlet (BSP) |
inch |
1.1/2" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1766 |
|
height |
mm |
1409 |
|
|
net weight |
kg |
435 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
1835 |
|
height |
mm |
1615 |
|
|
gross weight |
kg |
460 |
Sound
pressure level |
dB(4) |
A |
56 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-55
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-55 |
Duty |
cooling capacity @ 15°C(1) |
kW |
53 |
cooling capacity @ 7°C(2) |
kW |
37.5 |
|
|
compressor power(3) |
kW |
12.5 |
Electric
supply |
V/Ph/Hz |
380-415/3/56 |
|
nominal current(1) |
A |
23 |
|
|
maximum current |
A |
33.5 |
Compressor |
No. of compressor |
1 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.56 |
|
|
nominal air flow(1) |
m³/h |
17200 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.1 |
|
water flow(1) |
m³/h |
6.9/12 |
|
|
available pressure(1) |
kPa |
290/185 |
Tank capacity |
tank |
L |
300 |
Water
connections |
inlet/outlet (BSP) |
inch |
1.1/2" |
Dimensions of
unit |
width |
mm |
743 |
depth |
mm |
1966 |
|
height |
mm |
1519 |
|
|
net weight |
kg |
460 |
Dimensions of
package |
width |
mm |
880 |
depth |
mm |
2035 |
|
height |
mm |
1725 |
|
|
gross weight |
kg |
490 |
Sound
pressure level |
dB(4) |
A |
57 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-70
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-70 |
Duty |
cooling capacity @ 15°C(1) |
kW |
63 |
cooling capacity @ 7°C(2) |
kW |
45 |
|
|
compressor power(3) |
kW |
2×7.3 |
Electric
supply |
V/Ph/Hz |
380-415/3/57 |
|
nominal current(1) |
A |
27.5 |
|
|
maximum current |
A |
38.6 |
Compressor |
No. of compressor |
2 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.56 |
|
|
nominal air flow(1) |
m³/h |
17200 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.5 |
|
water flow(1) |
m³/h |
7.6/12 |
|
|
available pressure(1) |
kPa |
385/235 |
Tank capacity |
tank |
L |
400 |
Water
connections |
inlet/outlet (BSP) |
inch |
2" |
Dimensions of
unit |
width |
mm |
892 |
depth |
mm |
2330 |
|
height |
mm |
2055 |
|
|
net weight |
kg |
800 |
Dimensions of
package |
width |
mm |
990 |
depth |
mm |
2435 |
|
height |
mm |
2250 |
|
|
gross weight |
kg |
845 |
Sound
pressure level |
dB(4) |
A |
58 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-90
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-90 |
Duty |
cooling capacity @ 15°C(1) |
kW |
90.5 |
cooling capacity @ 7°C(2) |
kW |
66 |
|
|
compressor power(3) |
kW |
2×12.3 |
Electric
supply |
V/Ph/Hz |
380-415/3/58 |
|
nominal current(1) |
A |
47.7 |
|
|
maximum current |
A |
69.8 |
Compressor |
No. of compressor |
2 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.96 |
|
|
nominal air flow(1) |
m³/h |
26856 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.85 |
|
water flow(1) |
m³/h |
12.1/25 |
|
|
available pressure(1) |
kPa |
290/110 |
Tank capacity |
tank |
L |
400 |
Water
connections |
inlet/outlet (BSP) |
inch |
2" |
Dimensions of
unit |
width |
mm |
892 |
depth |
mm |
2330 |
|
height |
mm |
2055 |
|
|
net weight |
kg |
880 |
Dimensions of
package |
width |
mm |
990 |
depth |
mm |
2435 |
|
height |
mm |
2250 |
|
|
gross weight |
kg |
950 |
Sound
pressure level |
dB(4) |
A |
59 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-105
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-105 |
Duty |
cooling capacity @ 15°C(1) |
kW |
103 |
cooling capacity @ 7°C(2) |
kW |
76 |
|
|
compressor power(3) |
kW |
2×12.5 |
Electric
supply |
V/Ph/Hz |
380-415/3/59 |
|
nominal current(1) |
A |
48 |
|
|
maximum current |
A |
70 |
Compressor |
No. of compressor |
2 |
|
Number of circuits |
1 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
1.96 |
|
|
nominal air flow(1) |
m³/h |
26800 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
1.85 |
|
water flow(1) |
m³/h |
13.9/25 |
|
|
available pressure(1) |
kPa |
280/110 |
Tank capacity |
tank |
L |
400 |
Water
connections |
inlet/outlet (BSP) |
inch |
2" |
Dimensions of
unit |
width |
mm |
892 |
depth |
mm |
2330 |
|
height |
mm |
2055 |
|
|
net weight |
kg |
880 |
Dimensions of
package |
width |
mm |
990 |
depth |
mm |
2435 |
|
height |
mm |
2250 |
|
|
gross weight |
kg |
950 |
Sound
pressure level |
dB(4) |
A |
59 |
Note: |
|||
(1) water outlet temp = 15°C ; water
DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-150
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-150 |
Duty |
cooling capacity @ 15°C(1) |
kW |
152 |
cooling capacity @ 7°C(2) |
kW |
109 |
|
|
compressor power(3) |
kW |
4×9.2 |
Electric
supply |
V/Ph/Hz |
380-415/3/60 |
|
nominal current(1) |
A |
76.4 |
|
|
maximum current |
A |
108.7 |
Compressor |
No. of compressor |
4 |
|
Number of circuits |
2 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
4.00 |
|
|
nominal air flow(1) |
m³/h |
44000 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
5.5 |
|
water flow(1) |
m³/h |
19.3/60 |
|
|
available pressure(1) |
kPa |
335/205 |
Tank capacity |
tank |
L |
600 |
Water
connections |
inlet/outlet (BSP) |
inch |
2.1/2" |
Dimensions of
unit |
width |
mm |
1250 |
depth |
mm |
3694 |
|
height |
mm |
1976 |
|
|
net weight |
kg |
1695 |
Dimensions of
package |
width |
mm |
1395 |
depth |
mm |
3815 |
|
height |
mm |
2230 |
|
|
gross weight |
kg |
1745 |
Sound
pressure level |
dB(4) |
A |
63 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |

HL i-180
- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C

- Evaporator Tank
- Microprocessor Control
- Special Coated Condenser Fins for Longer Life
- Integral Stainless Steel Water Tank
- Adjustable LP Switch
- Centrifugal Stainless Steel Pump
- Heavy Duty Industrial Condenser Fan
- Reliable Compressor
- 100% Non-Ferrous Water Circuit
- Ambient Temperature: From -10°C to 43°C
- Water Temperature: From -5°C to 35°C
Model |
|
|
HL i-180 |
Duty |
cooling capacity @ 15°C(1) |
kW |
182 |
cooling capacity @ 7°C(2) |
kW |
131 |
|
|
compressor power(3) |
kW |
4×12.3 |
Electric
supply |
V/Ph/Hz |
380-415/3/61 |
|
nominal current(1) |
A |
93.6 |
|
|
maximum current |
A |
135 |
Compressor |
No. of compressor |
4 |
|
Number of circuits |
2 |
||
|
Refrigerant |
|
R407c |
Axial Fans |
No. of fan |
2 |
|
total nominal power |
kW |
4.00 |
|
|
nominal air flow(1) |
m³/h |
44000 |
Pump 3bar |
No. of pump |
1 |
|
total nominal power |
kW |
5.5 |
|
water flow(1) |
m³/h |
23.2/60 |
|
|
available pressure(1) |
kPa |
330/205 |
Tank capacity |
tank |
L |
600 |
Water
connections |
inlet/outlet (BSP) |
inch |
2.1/2" |
Dimensions of
unit |
width |
mm |
1250 |
depth |
mm |
3694 |
|
height |
mm |
1976 |
|
|
net weight |
kg |
1700 |
Dimensions of
package |
width |
mm |
1395 |
depth |
mm |
3815 |
|
height |
mm |
2230 |
|
|
gross weight |
kg |
1750 |
Sound
pressure level |
dB(4) |
A |
63 |
Note: |
|||
(1) water outlet temp = 15°C ;
water DELTA T = 5°C; ambient temperature = 25°C. |
|||
(2) water outlet temp = 7°C ;
water DELTA T = 5°C; ambient temperature = 32°C. |
|||
(3) refers to compressor, fans,
and pump absorbed power. |
|||
(4) refers in free field at 10m
distance from the unit at condenser side and at 1.2m from the ground. |